Microscope Magnification Calculator

Total microscope magnification is the product of objective magnification and eyepiece magnification. Standard combinations range from 40x to 1000x for biological samples.

🔬 Optics📐 M = Mₒₕⱼ × Mᵉᵙᵉ🧪 Biology
Objective Magnification
Eyepiece Magnification
Numerical Aperture (NA)
Wavelength (nm)
Please enter valid values.

Formula & Reference

VariableSymbolFormulaUnits
Total MagnificationMM = Mobj × Meye×
Objective MagMobj4x, 10x, 40x, 100x×
Eyepiece MagMeyeUsually 10x or 15x×
Resolutiondd = 1.22λ/(2 NA)nm

Step-by-Step Examples

Example 1
Standard Setup

Objective 40x, eyepiece 10x.

  • M = 40 * 10 = 400x
  • Resolution: NA=0.65, lambda=550 nm: 0.52 um
✓ 400x magnification, 0.52 um resolution
Example 2
Oil Immersion

Objective 100x oil (NA=1.3), eyepiece 10x.

  • M = 100 * 10 = 1000x
  • Resolution = 1.22*550/(2*1.3) = 258 nm
✓ 1000x, 258 nm resolution — limit of optical microscopy
Example 3
Low Power Survey

4x objective, 10x eyepiece.

  • M = 4 * 10 = 40x
  • Useful for initial scan of large samples
✓ 40x — low power survey magnification

Real-World Applications

🧬
Biology
Cell structures visible at 400x; bacteria at 1000x with oil immersion.
💉
Medical Diagnosis
Pathology uses 100-400x to examine tissue sections for disease.
🧪
Microbiology
Bacteria (1-10 um) visible at 400-1000x. Viruses require electron microscopy.
💎
Materials Science
Metallographic microscopes examine grain structure in metals at 50-1000x.

Common Mistakes to Avoid

⚠️
Total magnification is product, not sum

M = M_obj * M_eye. 40x objective with 10x eyepiece = 400x total, not 50x.

⚠️
Higher magnification needs oil immersion

Above 600x, oil immersion (n=1.515) between objective and slide increases NA and resolution.

⚠️
Empty magnification

Beyond ~1000x in optical microscopy, magnification is empty — no additional detail is revealed due to diffraction limit.

Frequently Asked Questions

What is empty magnification?
Magnification beyond what resolution supports. You see larger but not more detail. Optical microscopes are limited to ~1000x useful magnification.
What does NA mean?
Numerical Aperture = n*sin(alpha) where alpha is half the acceptance angle. Higher NA captures more diffracted light, giving better resolution.
Why use oil immersion?
Oil (n=1.515) between objective and coverslip increases NA from ~0.65 (air, 40x) to ~1.3 (oil, 100x), improving resolution by 2x.
How small can optical microscopes see?
Diffraction limit: d = lambda/(2*NA) ~ 200 nm with green light and NA=1.4. Viruses (20-200 nm) cannot be resolved. Electron microscopes needed.
What is confocal microscopy?
Uses pinhole to reject out-of-focus light, allowing 3D imaging by optical sectioning. Same magnification as conventional but much better contrast.