Fick Cardiac Output Calculator
Calculate cardiac output using Fick principle from oxygen consumption and arteriovenous O2 difference.
Why the a–v Difference Widens in Heart Failure
The Fick principle rearranges oxygen consumption into cardiac output. The clinically important consequence is that when output falls, tissues extract more oxygen from each unit of blood to maintain delivery.
| State | a–v difference | Mixed venous saturation |
|---|---|---|
| Normal rest | 4–5 mL/dL | 70–75% |
| Heart failure | 8–10 mL/dL | < 60% |
| Exercise | 12–15 mL/dL | 25–35% |
| Sepsis | Narrow | Often > 75% |
This makes mixed venous oxygen saturation a direct index of the adequacy of cardiac output. A low SvO2 means tissues are extracting hard because delivery is inadequate.
Sepsis inverts the pattern, which is diagnostically valuable. Microcirculatory shunting and impaired mitochondrial oxygen use mean tissues cannot extract normally, so SvO2 stays high despite tissue hypoxia. A high SvO2 in a shocked patient points to distributive rather than cardiogenic shock.
The Factor of 10, and Where VO2 Comes From
The multiplier converts mL O2 per dL into mL per L, since oxygen content is reported per decilitre and cardiac output in litres. Omitting it gives an answer ten times too large.
Direct measurement of VO2 requires expired gas collection, which is cumbersome. Most clinical applications use the indirect Fick, estimating VO2 from body surface area — typically 125 mL/min/m². That assumption is the method's largest error source, since real VO2 varies with sedation, fever and agitation.
| Method | Advantage | Limitation |
|---|---|---|
| Direct Fick | Reference standard | Requires expired gas collection |
| Indirect Fick | Practical | VO2 assumed, not measured |
| Thermodilution | Quick, repeatable | Overestimates in tricuspid regurgitation and low output |
Fick is preferred over thermodilution precisely in low output states and significant tricuspid regurgitation, where thermodilution systematically overestimates.
Worked Examples
Common Mistakes
Oxygen content is per decilitre and cardiac output in litres. Without the conversion the answer is ten times too high.
Anaemia, hypoxaemia and raised oxygen demand all lower it. The a–v difference reflects the balance of delivery and consumption, not output alone.
Impaired extraction keeps SvO2 high despite tissue hypoxia. A high value in a shocked patient suggests distributive rather than cardiogenic shock.
It systematically overestimates in both. Fick is the preferred method in those situations.